Acquiring and Displaying Waveforms
3–36
TDS 500C, TDS 600B, & TDS 700C User Manual
Figure 3–17: Acquire Menu — Stop After
Press RUN/STOP button only (side) to use the RUN/STOP button to start
or stop acquiring. Pressing the RUN/STOP button once will stop the
acquisitions. The upper left hand corner in the display will say “Stop” and
show the number of acquisitions. If you press the button again, the oscillo-
scope will resume taking acquisitions.
Press Single Acquisition Sequence (side). That selection lets you run a
single sequence of acquisitions by pressing the RUN/STOP button. In
Sample, Peak Detect, or Hi Res mode, the oscilloscope will acquire a
waveform record with the first valid trigger event and stop. (Hi Res is
available only on TDS 500C and TDS 700C models.)
In Envelope or Average mode, the oscilloscope will make the specified
number of acquisitions to complete the averaging or enveloping task.
TDS 500C and TDS 700C models only: If the oscilloscope is in equivalent-
time mode and you press Single Acquisition Sequence (side), it will
continue to recognize trigger events and acquire samples until the waveform
record is filled.