Operators Checkout Procedure
2-20
1740A/1750A Series Waveform/Vector Monitor User Manual
VECTOR PHASE
FLAT
LUM
CHROM
DIFF
R--Y
F+L
F+L+C
SCH R-- Y
Figure 2-12. Two-Field SC/H R ---Y display (PAL), showing proper SCH phase.
9. Line Selection
Line select is available in the following display modes:
WAVEFORM, VECTOR, SCH (1750A--Series only), and PIC-
TURE
. Enter the LINE SELECT menu and turn the center bezel
control until the readout displays
ALL 131. In a two line
display, line 131 appears on the left, followed by line 132.
Select
2FIELDsweep and note the intensified line in each
field. Select
15H and note that 15 lines are now intensified in
each field (intensified portion appears wider). The readout i s
now
ALL 131-- -- 145. See Figure 2-13.