Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4PWR application module.
Group
Power
Syntax
POWer:HARMonics:MIL:POWER LEVel {LOW|HIGH}
POWer:HARMonics:MIL:POWER LEVel?
Arguments
LOW species low power level for MIL-STD-1399 harmonics tests.
HIGH species high power level for MIL-STD-1399 harmonics tests.
Examples
POWER:HARMONICS:MIL:POWER LEVEL HIGH sets the MIL power level to High.
POWER:HARMONICS:MIL:POWER LEVEL? might return
:POWER:HARMONICS:MIL:POWE RLEVEL LOW indicating that the MIL power
level is set to Low.
POWer:HARMonics:NR_HARMonics
Sets or returns the number of harmonics (value ranging from 20 to 400) when the
harmonics standard is NONe.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:HARMonics:NR_HARMon ics <NR3>
POWer:HARMonics:NR_HARMon ics?
Arguments
<NR3> is the number of harmonics.
Examples
POWER:HARMONICS:NR_HARMON ICS 100 sets the number of harmonics to 100.
POWER:HARMONICS:NR_HARMON ICS? might return
:POWer:HARMonics:NR_HARMO NICS 40 indicating that the number of
harmonics is set to 40.
POWer:HARMonics:RESults:HAR<1-400>:FREQuency? (Query Only)
Returns the frequency of the harmonic.