Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray :DATa:OFFSet <NR1>
TRIGger:A:BUS:B<x>:FLEXray :DATa:OFFSet?
Arguments
<NR1> is the offset of the data string in bytes. A byte offset of -1 signies don’t
care, and no byte offset is used. The instrument will trigger or match any byte
value that ts.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:D ATA:OFFSET? might return
TRIGGER:A:BUS:B1:FLEXRAY:D ATA:OFFSET 0 indicating that a data offset
of 0.
TRIGGER:A:BUS:B1:FLEXRAY:D ATA:OFFSET? might return
TRIGGER:A:BUS:B1:FLEXRAY:D ATA:OFFSET 0 indicating that a data offset
of 0.
TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALier
Sets or returns the FLEXRAY data qualier.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray :DATa:QUALifier
{LESSThan|MOREThan|EQUal|U NEQual|LESSEQual|MOREEQual|
INrange|OUTrange}
TRIGger:A:BUS:B<x>:FLEXray :DATa:QUALifier?
Arguments
LESSThan sets the FLEXRAY data qualier to less than.
MOREThan sets the FLEXRAY data qualier to greater than.
EQUal sets the FLEXRAY data qualier to eqaual.
UNEQual sets the FLEXRAY data qualier to not equal.
LESSEQual sets the FLEXRAY data qualier to less than or equal.
MOREEQual sets the FLEXRAY data qualier to greater than or equal.
INrange sets the FLEXRAY data qualier to in range.
OUTrange sets the FLEXRAY data qualier to out of range.
MSO4000 and DPO4000 Series Programmer Manual 2-405